Rob Pearce ee7751ffd5 | ||
---|---|---|
img | ||
README.md | ||
aircon.sh | ||
aircon_grafana.png | ||
myair_cmds |
README.md
Overview
Script to automate control of an home reverse cycle aircon system based on custom logic and temperature measurements.
This was originally written for an AdvantageAir system. It just uses the myair API to interface with the aircon, so should be easily adaptable to other systems.
It can also log to an influxdb database for easy integration into Grafana or similar.
Features
- Define temperature rules based on weekday and/or time
- Automatically adjust aircon settings based on defined temperature thresholds
- Control zone temperature by opening/closing vents
- Open/close vents in adjacent zones to assist in temperature control
- Turn the entire aircon system on/off as needed to control temperature
- Turn zones on/off based on ARP table entries for specific MAC addresses (for example, if a TV is turned on or a person's phone is detected)
- Log temperature measurements to a CSV file or InfluxDB
Usage
usage: ./aircon.sh [options]
Modifies aircon based on configured parameters in /Users/rob/.airconrc.
-a file Specify location of arping binary (default: /usr/local/sbin/arping).
-b Rule debug mode. Show processing of time rules.
-A db Log actions to given influxdb database.
-c Cron mode. Only show output if actions were taken.
-D dbhost Specify influxdb hostname for -I and -A options (default: localhost)
-f file Specify an alternate config file.
-h Show this text.
-i x.x.x.x Specify IP address for aircon (default is 10.99.99.1)
-I db Log all zone temperatures to given influxdb database, then exit (see -o).
-k file If file exists, never change aircon settings (default: /Users/rob/.aircon_noaction).
-l num Set number of too hot/cold zones at which to taking action.
-L Log all zone temperatures to CSV file, then exit (see -o).
-m Generate a config file based on current aircon setup.
-o file Specify CSV output file. Default: /Users/rob/acstats.csv
-P Use pymyair instead of direct JSON API calls (also see -x).
-p Profiler mode.
-s Validate config file then exit.
-S[H] Show configured rules in human-readable format
(HTML if -H given, otherwise ANSI).
-t num Specify degrees below min temperature before taking action.
-T num Specify degrees above max temperature before taking action.
-w List which people are available then exit.
-W List zone-owning devices are available then exit.
-x path Specify location of 'pymyair' (from https://github.com/smallsam/pymyair)
(only used if -P specified)
-y Actually run commands/db inserts. By default, commands are just displayed.
Examples
Sample .airconrc file
root@gridbug:~# cat .airconrc
options -t 0.5
modelock heat
constant Family
owner Study robsphone
owner Rob&Beth robsphone bethsphone
owner Brendan brendansphone
owner Media lgtv_wifi
@Thu-Fri;0830-1630 force Nursery close # Childcare hours
@1830-0630 temp Nursery 17-19
@0600-2359 temp Family 18-21
temp Media 18-22
temp Rob&Beth 18-22
@Mon-Fri;0830-1730 temp Study 18-22 # Rob working
@Sat-Sun ignore Study # Not working
adj Brendan Family
adj Media Brendan
adj Rob&Beth Family
adj Study Family
person Rob robsphone
person Beth bethsphone
person Brendan brendansphone
Generate ~/.airconrc based on your actual aircon zones
bash$ aircon.sh -m
Log temperature for each zone to csv then exit
bash$ aircon.sh -L -o /root/acstats.csv -x /usr/local/bin/pymyair -f /root/.airconrc
Preview influxdb inserts for zone temperatures
bash$ aircon.sh -I myinfluxdb
/usr/local/bin/influx -database myinfluxdb -execute INSERT temperature,room=Family value=18.7
/usr/local/bin/influx -database myinfluxdb -execute INSERT temperature,room=Brendan value=19.1
/usr/local/bin/influx -database myinfluxdb -execute INSERT temperature,room=Media value=21
/usr/local/bin/influx -database myinfluxdb -execute INSERT temperature,room=Rob&Beth value=18.4
/usr/local/bin/influx -database myinfluxdb -execute INSERT temperature,room=Study value=19.2
/usr/local/bin/influx -database myinfluxdb -execute INSERT temperature,room=Nursery value=17.8
/usr/local/bin/influx -database myinfluxdb -execute INSERT attendance,person=Rob value=1
/usr/local/bin/influx -database myinfluxdb -execute INSERT attendance,person=Beth value=1
/usr/local/bin/influx -database myinfluxdb -execute INSERT aircon running=0
/usr/local/bin/influx -database myinfluxdb -execute INSERT aircon mode=0
Log temperature for each zone to local influxdb then exit
bash$ aircon.sh -I myinfluxdb -y
Determine required aircon changes and display them only (dry run)
bash$ aircon.sh
Aircon mode: heat (locked to heat)
Current myzone: Family (zone 1)
Tolerance: 0.5 degrees low, 0 degrees high
Valid Set Actual Proposed
Zone Temp State Temp Temp Action
Family (C) 18-21 open 19 21.6 close_vent
Brendan n/a close 19 19.3 n/a
Media 18-22 close 20 21.6 n/a
Rob&Beth 18-22 close 18 19.5 n/a
Study n/a close 19 20.6 n/a
Bedroom2 18-21 close 18 19.5 n/a
Nursery 17-19 open 19 18.9 set_myzone
Analysis:
- Family is too hot (constant zone)
Proposed commands:
myair 10.99.99.1 set --zone 1 --state off --temp 19 # In zone Family, close vent
myair 10.99.99.1 myzone --zone 7 # Set MyZone to Nursery
Make required aircon changes
bash$ aircon.sh -y
Aircon mode: heat (locked to heat)
Current myzone: Family (zone 1)
Tolerance: 0.5 degrees low, 0 degrees high
Valid Set Actual Proposed
Zone Temp State Temp Temp Action
Family (C) 18-21 open 19 21.6 close_vent
Brendan n/a close 19 19.3 n/a
Media 18-22 close 20 21.6 n/a
Rob&Beth 18-22 close 18 19.5 n/a
Study n/a close 19 20.6 n/a
Bedroom2 18-21 close 18 19.5 n/a
Nursery 17-19 open 19 18.9 set_myzone
Analysis:
- Family is too hot (constant zone)
Proposed commands:
myair 10.99.99.1 set --zone 1 --state off --temp 19 # In zone Family, close vent
myair 10.99.99.1 myzone --zone 7 # Set MyZone to Nursery
Running action: In zone Family, close vent
RUNNING myair 10.99.99.1 set --zone 1 --state off --temp 19
Running action: Set MyZone to Nursery
RUNNING myair 10.99.99.1 myzone --zone 7
Make required aircon changes and log actions to influxdb
bash$ aircon.sh -y -A myinfluxdb
Make required aircon changes and only produce output if actions taken (cron mdoe)
bash$ aircon.sh -y -c
Show which zone owners are detected, then exit
bash$ aircon.sh -W
Devices Availability
bethsphone Available
brendansphone Available
lg-wifi Unavailable
robsphone Available
Dump current rules, showing which ones are active (use -SH for HTML format)
root@gridbug:scripts# ./aircon.sh -S
>> Querying aircon... ok
- Only operate the aircon in heat mode
- Close vent in Media if lg-wifi isn't online
- Close vent in Study if robsphone isn't online
- Close vent in Rob&Beth if one of (robsphone bethsphone) aren't online
- Close vent in Brendan if brendansphone isn't online
- Ignore Brendan temperature when deciding what to do
- Ignore Nursery temperature when deciding what to do
- Force the vent in Nursery to be closed
- [out-of-hours] From Mon to Fri between 08:30 and 18:00, Close vent in Ben/Sewing if brendanslaptop isn't online
- Prevent Nursery from being the MyZone
- Prevent Ben/Sewing from being the MyZone
- [out-of-hours] From Mon to Tue between 08:30 and 16:30, Force the vent in Nursery to be closed
- [out-of-hours] Between 08:30 and 16:30, Force the vent in Nursery to be closed
- [ignored] Keep temperature of Nursery between 25-26 degrees
- From Sat to Sun, Ignore Study temperature when deciding what to do
- [out-of-hours] From Mon to Fri between 08:30 and 18:00, Close vent in Ben/Sewing if brendansphone isn't online
- Between 06:00 and 23:59, Keep temperature of Family between 18-21 degrees
- [ignored] Keep temperature of Brendan between 18-20 degrees
- [out-of-hours] Between 20:00 and 07:00, Keep temperature of Rumpus between 18-22 degrees
- Keep temperature of Media between 18-21 degrees
- Keep temperature of Rob&Beth between 18-22 degrees
- [out-of-hours] From Mon to Fri between 08:30 and 17:30, Keep temperature of Study between 18-22 degrees
- [out-of-hours] Between 19:30 and 06:30, Keep temperature of Nursery between 18-19 degrees
- [out-of-hours] Between 20:00 and 07:00, Keep temperature of Ben/Sewing between 18-22 degrees
- [out-of-hours] From Mon to Fri between 08:30 and 17:30, Keep temperature of Ben/Sewing between 17-22 degrees